CANdb Import Add-in 3 Version History
18.04.2013 - Version 3.0.11 -
released with PCAN-Explorer 5.3.2
Change:
- When importing a Multiplexer signal that had a value table assigned, not all defined Multiplexer values were imported if the number of value table entries was smaller than the number of different Multiplexer values
06.09.2012 - Version 3.0.10 - released with PCAN-Explorer 5.3.0
Change:
- New possibility to control the optimized import of value tables. Usually, identical enums are not imported twice, which can now be turned off by setting a registry value
14.05.2012 - Version 3.0.9 - released with PCAN-Explorer 5.2.2
Bug fixes:
- Version 3.0.8 introduced the bug that variables and multiplexers in Motorola format were not imported correctly
30.03.2012 - Version 3.0.8.68 - released with PCAN-Explorer 5.2.1
Bug fixes:
- When importing value tables for signals, value table entries could be lost
- Signals that overlapped other signals in the data bytes were not imported
- If a Symbol was exported that had the "Valid for all Data Lengths" option activated, the resulting .dbc file was defective
26.01.2012 - Version 3.0.6.65 - released with PCAN-Explorer 5.2.0
Bug fixes:
- If a CANdb file was added to a new PCAN-Explorer project and the file was applied for the first time, all messages from the file were imported even if no messages were selected in the list of the CANdb window
- If a signal was imported that had both Min and Max parameters set to 0, then the signal’s GenSigStartValue attribute was ignored
26.05.2011 - Version 3.0.5.58 - released with PCAN-Explorer 5.1.4
- Bug fix: Some memory leaks fixed
- Improvements: The message attribute GenMsgCycleTime is now evaluated when importing a CANdb file
07.04.2011 - Version 3.0.4.56 - released with PCAN-Explorer 5.1.3
Bug fixes:
- If a CANdb file was opened in the Library browser, no messages were preselected in the DBC file window. But if the Apply button was pressed, all messages were imported
Improvements:
- Messages of protocol type ISO 11783 are treated as J1939 messages
- If J1939 messages are imported and the J1939 Add-in is not loaded, the messages are imported as extended messages if the data length is between 0 and 8
18.10.2010 - Version 3.0.3.52 - released with PCAN-Explorer 5.1.2
Bug fixes:
- When importing a CANdb database in PCAN Symbol Editor, an error message was displayed if the comment text of a message or a signal contained escape codes (e.g. "\n", Line Feed)
01.09.2010 - Version 3.0.2.51 - released with PCAN-Explorer 5.1.0
- Bug fix: More memory leaks fixed
- Improvement: Importing and exporting of J1939 symbols (if the J1939 Add-in is installed and loaded)
23.11.2009 - Version 3.0.1.47
- Bug fix: Memory leaks fixed