PCAN-Ethernet Gateway DR
CAN to LAN Gateway in DIN Rail Plastic Casing

PCAN-Ethernet Gateway DR
IPEH-004010 € 260,00

All prices are plus the at present valid value added tax!

Description

The PCAN-Ethernet Gateway DR allows the connection of different CAN busses over IP networks. CAN frames are wrapped in TCP or UDP message packets and then forwarded via the IP net from one device to another.

The PCAN-Ethernet Gateway DR provides one LAN connection and two High-speed CAN interfaces. With its DIN rail casing and the support of the extended temperature range, the module is suitable for use in an industrial environment.

The configuration of the device is done via a comfortable web interface. Besides a variety of status information, settings for the device itself, for the communication interfaces, and for message routing are provided.

Technical Specifications

  • ARM9 Freescale iMX257 with 16 kByte Level 1 Cache and 128 kByte internal SRAM
  • 256 MByte NAND Flash and 64 MByte DDR2 RAM
  • Linux operating system (version 2.6.31)
  • RS-232 connector for serial data transfer (reserved for future use)
  • Connections for CAN, RS-232, and power supply via 4-pole screw-terminal strips (Phoenix)
  • Reboot and reset of the device to factory defaults with a reset button
  • Configuration of the network interfaces and the message forwarding through a web interface
  • Plastic casing (width: 22.5 mm) for mounting on a DIN rail (DIN EN 60715 TH35)
  • LEDs for device status and power supply
  • Voltage supply from 8 to 30 V
  • Extended operating temperature range from -40 to 85 °C (-40 to 185 °F)

LAN properties

  • Data transmission using TCP or UDP
  • 10/100 Mbit/s bit rate
  • RJ-45 connector with status LEDs

CAN properties

  • Two High-speed CAN channels (ISO 11898-2)
  • Bit rates from 5 kbit/s up to 1 Mbit/s
  • NXP PCA82C251 CAN transceiver
  • Galvanic isolation of the CAN channels up to 500 V against each other, against RS-232 and the power supply
  • Compliant with CAN specifications 2.0A and 2.0B

Configuration

The configuration of the gateways is done via a web interface. Therefore, the module must be connected to the PC via LAN or WLAN according to the model. Afterwards, a common web browser is suitable to access the device. The device‘s web interface opens and displays public information about the device status and the message forwarding. In order to configure the device, a login on the website is required. Depending on the hardware, corresponding settings are available.

Functions of the Web Interface

  • Display of status information about the communication interfaces and the message forwarding
  • Definition of the public visibility of status information
  • Import and export of device configurations
  • Reset of the device configuration to factory defaults
  • Comfortable software updates
  • Scan of the IP network for further available PCANGateways for an easier establishment of routes
  • Layout automatically adjusts for mobile devices
  • Rebooting the device via the website
  • Integrated Help pages

CAN channel settings:

  • Selection of bit rates up to 1 Mbit/s from a preset list
  • Setup of user defined bit rates via register values
  • Status switching of the listen-only mode

LAN interface settings:

  • Automatic or manual setup of the device‘s IP address (IPv4) and the subnet mask

Setup and management of the message forwarding:

  • Setup of the message forwarding between a CAN channel and LAN/WLAN (or vice versa)
  • Selection of the participating CAN channel
  • Definition of the LAN/WLAN station according to the IP address and the port
  • Selection of the transfer protocol TCP or UDP
  • Enabling, disabling, and editing of existing routes
  • Disabling the PCAN-Gateway Handshake to allow the connection to other devices

Properties of the message filtering:

  • Creating and managing filters via a new section of the web interface
  • Creating Filters with different options:
    • Filtering messages with 11-bit or 29-bit IDs
    • Support of range and mask filters
    • Optional inversion of the filter range
  • Assigning a filter to multiple routes

Scope of supply

  • PCAN-Ethernet Gateway DR in DIN rail plastic casing
  • Mating connectors for both CAN channels, RS-232, and power supply
  • RJ-45 network patch cord (2 m)
  • Manual in PDF format
  • Printed quick start guide

Downloads

PCAN-Ethernet Gateway DR package

This package is used to update the software and configuration website of the PCAN-Ethernet Gateway DR (IPEH-004010).

PCAN-Ethernet Gateway DR manual

PCAN-Gateway developer documentation

PCAN-Gateway quick start

Virtual PCAN-Gateway setup

This is the PEAK-System installation package for device drivers and tools for Windows® 10, 8.1, 7 (32/64-bit).

Please note: Select the Virtual PCAN-Gateway from the available options during the installation.

Virtual PCAN-Gateway manual

More

Additional information on other pages:

PCAN-Gateway version history
PEAK-System Forum: Section for the PCAN-Ethernet Gateway DR for questions and support
YouTube: With short video tutorials, we demonstrate how to use the PCAN-Gateways

Accessories:

PCAN-D-Sub Connection Adapter