PCAN-View Version History
07.03.2012 - Version 3.2.0.212
Improvements:
- New Comment column in the Transmit list
- Error Generator (PCAN-USB Pro): The entered CAN-ID is always converted to Hex when leaving the edit field
- The position of a message in the Transmit list can be changed by pressing [Ctrl+Arrow Up] / [Ctrl+Arrow Down]
Bug fixes:
- The data bytes of selected transmit messages were not clipped to the data column if the column was too narrow
- Connection dialog box: The bit rate of a selected hardware was not always shown correctly
- The start time of a trace was not correctly written to the trace file
18.07.2011 - Version 3.1.5.200
Improvements:
- The tracer will start automatically after establishing a connection if it was still active when the program was last exited
Bug fixes:
- Messages that were transmitted on the same PCAN net by another application, and which were using the SingleShot CAN controller option, were not shown in the Receive list
- Connection dialog box: If the channel number of a CAN hardware was higher than 2, the displayed channel number was not correct
17.03.2011 - Version 3.1.4.195
Bug fixes:
- After the user interface language was changed from German to English, an Access Violation could occur when exiting the program
- After deleting messages from the Transmit list, the entire list content was sometimes shifted to the left so that the ID column was no longer visible
08.03.2011 - Version 3.1.3.194
Bug fixes:
- When using the "Windows Classic" design under Windows Vista or later an error occurred every time the application showed a message box
- The Tracer stored an incorrect start time in the trace file
01.02.2011 - Version 3.1.2.193
Improvements:
- New menu command File->Language->Automatic
- If an 11-bit filter range was set, PCAN-View also received messages with IDs outside the selected ID range
- A warning message is shown before the 5V output is activated on the CAN connector of a PCAN-PC Card, PCAN-ExpressCard, or PCAN-USB Hub
- The data bytes of CAN messages in the Receive and Transmit list are now shown with fixed width characters to prevent horizontal jitter when the data changes rapidly
Bug fix:
- PCAN-USB Pro: The labels for the maximum and minimum bus load indicators were interchanged
21.10.2010 - Version 3.1.1.186
Improvements:
- Under Windows 2000, or under Windows XP and later if using the "Windows Classic" design, the toolbar was painted with a style that looked out of place
- If the PCAN tools "PCAN Status Display" or "PCAN Nets Configuration" are found in the same directory where PCAN-View is located, a new menu "PCAN Tools" is shown that offers quick access to these tools
Bug fix:
- The trace mode indicator on the Trace tab was not painted correctly under Windows 2000 or under Windows XP and later if using the "Windows Classic" design
13.10.2010 - Version 3.1.0.182
Improvements:
- The user interface language can be switched between English and German
- The number of QXMTFULL errors that have occurred for cyclic transmit messages is displayed in the Status bar (requires PCAN driver version 3.5.2 or later)
Bug fixes:
- When sending messages manually, transmit errors were not processed and displayed, e.g. QXMTFULL
- After re-connecting PCAN-View, the error counters "Overrun" and "QXmtFull" in the Status bar were not set to 0
23.09.2010 - Version 3.0.9.160
Improvements:
- If a connected PCAN hardware is plugged out, the connection indicator in the Status bar is updated to show the correct (internal) hardware icon
- All labels "Baud rate" changed to "Bit rate"
Bug fix:
- If a connected PCAN hardware was plugged out, after opening the Connect dialog box again a wrong PCAN net was indicated as the connected net
17.06.2010 - Version 3.0.8.157
- Bug fix: Connect dialog box: An exception "List index out of bounds" occurred if a hardware was selected that already had another PCAN application to it, and which used a custom Bit rate setting
09.06.2010 - Version 3.0.7.155
- Bug fix: Because of a repaint problem it could happen that incorrect values were shown for the data bytes of a CAN message. Clicking on the message with the mouse then displayed the correct values
02.06.2010 - Version 3.0.6.153
Bug fixes:
- The Error Warning QOVERRUN was not recorded by the Tracer
- Transmitted RTR messages were not recorded by the Tracer
Changes:
- If tracing of Error Frames is activated, receiving of Error Frames is always enabled in the driver when starting the Tracer even if no hardware is plugged-in. If a hardware is plugged in during a recording, Error Frames can be recorded immediately without stopping and restarting the recording
26.05.2010 - Version 3.0.5.148
- Improvements: New PCAN-ExpressCard tab with the possibility to control the 5V output on the CAN connector of a PCAN-ExpressCard
14.05.2010 - Version 3.0.4.146
- Improvements: Identifying of CAN channels by flashing of the associated CAN LED can now also be performed for PCAN-USB hardware
22.04.2010 - Version 3.0.3.144
- Improvements: New command Help->Device Driver Version that can be used to show information about the device driver that is currently in use
14.04.2010 - Version 3.0.2.140
Bug fix:
- The hardware image on the PCAN-PC Card tab was missing.
Improvements:
- Support for the PCAN-USB Hub hardware: Possibility to change the device number and to control the PWR-OUT output on pin 9 of the CAN connector
- Hardware images of PCAN-USB and PCAN-USB Pro updated
06.04.2010 - Version 3.0.1.132
- Bug fix: If the option Tracer->Log Data Frames was deactivated, no more data frames were shown in the Receive list
26.03.2010 - Version 3.0.0.130
Changes:
- Only one PCAN-View for all devices: the Connection dialog box shows CAN hardware and nets (if available) from all devices (PCI, USB, PC Card, etc.)
- Loading and saving of transmit lists
- The messages in the Transmit list are stored in the Windows Registry when exiting the application and automatically restored when the program is started the next time
- New possibility to record messages
- Multiple messages can be selected in the message lists at the same time, and can be copied, cut, and pasted via the clipboard
- Possibility to set the Device Number of PCAN-USB, PCAN-USB Pro, and PCAN-PC Card
- The bus load measured by a PCAN-USB Pro hardware can be displayed
- Programming of the PCAN-USB Pro error generator.
- Tabbed user interface. The Tracer, Bus Load, and Error Generator tabs can be undocked from the main window
- Identifying of PCAN-USB Pro channels by flashing of the associated CAN LED
- Support of the new device driver for virtual CAN hardware