

Plotter Add-in 2 Version History
30.03.2012 - Version 2.2.1.145 -
released with PCAN-Explorer 5.2.1
Bug fixes:
- Under Windows® XP, Not-a-Number floating point signal values (NaN) caused "Severe error" messages and application crashes
- Unnecessary data cursor properties were saved to plotter files
- If a plotter file was loaded that had visible data cursors, the Data Cursor button in the toolbar did not reflect the visible data cursor state
26.01.2012 - Version 2.2.0.142 -
released with PCAN-Explorer 5.2.0
- Improvement: New possibility to export plot data to CSV files
- Bug fix: The signal name display mode that was selected in the PCAN-Explorer options had no effect on how signal names were displayed in the plotter
26.07.2011 - 2.1.1.128 - released with PCAN-Explorer 5.1.4
- Improvement: Channels are no longer automatically renamed according to assigned signals when loading a Plotter file
- Bug fix: The "Select Signals to Import" dialog box could be set behind the PCAN-Explorer main window, so that it seemed as if the application was not responding
07.04.2011 - Version 2.1.0.125 - released with PCAN-Explorer 5.1.3
Improvements:
- Object model: New method Channel.AddData to add own data points by macro or Add-in
- No automatic scaling of y-axes when adding or changing signals. The scaling of a y-axis can be stored as a default setting via the "Store as defaults" function
- New command "Zoom to fit Signal range" in the context menu of y-axes
- New command "Zoom to fit" in the context menu of the data view to zoom all axes in one step
- Enum values of signals are shown on y-axes
Bug fixes:
- When importing data from a Tracer, the Select Signals dialog box was sometimes shown behind the main application window on Windows 7 64-bit systems
07.09.2010 - Version 2.0.3.117 - released with PCAN-Explorer 5.1.0
Changes:
- The names of y-axes are now determined by the names of channels
Bug fixes:
- Displaying the Trace Import dialog box could take a long time, if large trace files were found in the default Trace folder
- Resetting the plotter settings did not work correctly
26.10.2009 - Version 2.0.2.113
Bug fixes:
- If the color of a y-axis title font was changed and then a recording started, the plotter changed the title font color back to the channel color
- Higher DPI settings caused display problems in the Properties dialog box
16.09.2009 - Version 2.0.1.110
Improvements:
- The Trace Import dialog box now shows all the Trace files that are included in the current project in the Current Tracers list
Bug fixes:
- Resetting the plotter settings did not delete the user’s custom settings file (defaults.dat) so that the next new plotter window again used the previous custom settings
- Importing of trace files was very slow



