We use cookies on our website to provide you with the best possible service and to further improve our website. By clicking the "Accept All" button, you agree to the use of all cookies. You can limit the cookies used by clicking on "Accept selection". Further information and an option to revoke your selection can be found in our privacy policy.

Necessary:

These cookies are necessary for basic functionality. This allows you to register on our website and forum or order products with our online shop.

Statistics:

With these cookies, we collect anonymized usage data for our website. For example, we can see which content is interesting for our visitors and which resolutions are used. We use the information to optimize our website to provide you with the best possible user experience.

Necessary
Statistics

show more

J1939 Add-in Version History

2016-09-01 - Version 1.6.3 -
released with PCAN-Explorer 5.4.1

Improvements:

  • Some code optimizations.

Bug fixes:

  • Prevention of internal access violations caused by parallel access to transmit sessions.
  • Transport protocol read session were refused by sending a TCPM.Abort message even if the connection was in monitoring mode and/or the claimed address did not correspond to the incoming request.

2015-09-30 - Version 1.6.0 - released with PCAN-Explorer 5.4.0

Improvements:

  • Sending multipacket broadcast messages is now possible without having to claim an address

Bug fixes:

  • Received messages could have wrong timestamps that would appear in the PCAN-Explorer tracer as very large values
  • A J1939 connection responded to a received RQST for PGN 60928 (Address Claimed, ACM) even if the RQST was a peer-to-peer request directed to a different destination address

2012-11-12 - Version 1.4.3 - released with PCAN-Explorer 5.3.1

Improvements:

  • Some minor internal improvements

2012-09-06 - Version 1.4.2 - released with PCAN-Explorer 5.3.0

Bug fixes:

  • In Peer-to-Peer transport protocol sessions sometimes an access violation error occurred
  • Object model: Some object properties could not be accessed by VBS macros, the properties used data types that were not Automation-compatible
  • Object model: The method J1939Node.GetSystemTime() incorrectly returned its value in an output parameter instead of a return value, so the method could not be called in a VBS macro

2012-05-14 - Version 1.4.0 - released with PCAN-Explorer 5.2.2

Improvement:

  • Support for device PCAN_VIRTUAL added

2011-04-07 - Version 1.3.11 - released with PCAN-Explorer 5.1.3

Improvement:

  • Speed of read and write sessions improved

2010-10-18 - Version 1.3.10 - released with PCAN-Explorer 5.1.2

Improvements:

  • CPU load reduced and performance improved
  • Addresses can now be claimed successfully even when the bus is in the BUSHEAVY state

Bug fixes:

  • Memory leaks fixed

2010-09-07 - Version 1.3.7 - released with PCAN-Explorer 5.1.0

Improvements:

  • Reassembling of incoming large message packets (TPDT) to complete messages can now be controlled via the new property "Reassemble Incoming Packets"
  • Object model: A new collection "J1939Filters" allows better access to the configured filters

Bug fixes:

  • Memory leaks fixed
  • Drag-and-drop of messages with more than 8 data bytes could result in an access violation
  • Some SPN values of diagnostic messages were not displayed correctly:
    • 19-bit SPNs 1214, 3036, and 3297
    • 11-bit SPNs 1640 and 1649
    • 12-bit SPN 1596