2023-03-03 - Version 1.3.0
Improvement:
- The copy and edit operation of the Trace Message filter file has been added
Please note: Downloadable only via the PCAN-Diag 2 package. This sorfware is not distributed individually.
Download
2015-09-29 - Version 1.2.1
- Bug fix: While converting Enums from Symbol files, empty strings were not handled correctly
2013-11-08 - Version 1.2.0
- It is now possible to select a multiplexer display mode (common or separate) for a symbol file
- Support for CAN ID mask of symbol files added
- Bug fix: If the Windows themes had been disabled, the toolbars were not displayed correctly
Please note: The PCAN-Diag Editor version 1.2.0 requires the PCAN-Diag firmware version 1.7.0.
2011-10-25 - Version 1.1.0
- The tab order on the tab "CAN Transmit Lists" was corrected
- Pre-selection of the first message of a transmit list, after selecting any desired list
- When saving the project file, under circumstances the last changed value of a transmit list message was not saved if the edit mode of this value was not completed
- The program icon in the Windows® taskbar was only displayed with 16x16 pixels
- When entering the user bitrates names under Device Settings, more than 10 characters could be entered, although the PCAN-Diag can only display 10 characters. The number is now, by definition, limited to 10 characters
- When entering the name of a transmit list, more than 20 characters could be entered, but then the input could not be taken. Now the input is limited to a maximum of 20 characters
- On the "CAN Transmit Lists" tab, the context menu command "Rename" has been added in order to rename a transmit list
- On the "CAN Transmit Lists" tab, a new value "Min. required cyle time" has been added
- The layout on the "CAN Transmit Lists" tab has been changed due to the new value
2011-08-22 - Version 1.0.3
- When the library "PcanDiagHlp.dll" could not be loaded in the program, the transfer was displayed without a meaningful error message. The same message was also produced by the older version 1.0.0.15 of the library. This error has been corrected
- Text corrections in the default file
2011-05-10 - Version 1.0.2
- Bug fix concerning reading the default file
- Bug fix concerning reading the project files (particularly affected numbers which were displayed as hexadecimal values in the program)
- Bug fix concerning an saving error, causing that, the last changed setting in the program was not saved
2011-04-27 - Version 1.0.1
- Error corrected that occurred when closing the program if it was started from the PCAN-Diag and the PCAN-Diag was removed from USB
- New attribute "FileVersion" in the default file was added
- When saving project files the following new values will be stored in the section "Version" : firmware version, file version and program version
- New command "Device Info...." was added to the toolbar
- Error corrected that occurred during the transfer when a transmitted symbol file could not be read for conversion
- Correction in the version information of the library "PcanDiagHlp.dll" (1.0.2.18)
- In the library "PcanDiagHlp.dll" (1.0.2.18) the new rules of the symbol format regarding the multiplexers in PCAN-Explorer versions 5.1.3 and higher were included
2011-02-24 - Version 1.0.0
- First official release version of PCAN-Diag Editor and the library for converting symbol files for the useage PCAN-Diag "PcanDiagHlp.dll" (1.0.1.17)