Ce site utilise des cookies à des fins d'analyse, de gestion de la connexion au site marchand, au forum et de traitement d’une commande. En continuant à naviguer sur ce site, vous acceptez cette utilisation. Vous trouverez des informations détaillées sur l'utilisation des cookies dans notre politique de confidentialité.

OK Confidentialité

PCAN-MicroMod FD Configuration Version History

2020-06-19 - Version 1.1.0

Improvements:

  • The Analog Inputs (16-bit) have been expanded to some information about measurement resolution of the selected range
  • The default name of Curve Definitions has been changed because the format of these names does not match to all other formats
  • When an invalid or not supported custom bit rate (e.g. prescaler out of range) is loaded or saved, a new warning message is shown in the Output window
  • When a configuration is sent with an invalid or not supported custom bit rate, an error message is shown in the Output window and the sending is aborted
  • Improved text output in the Output window with different colors
  • Improved handling of Bus-Off errors when trying to re-detect modules
  • New tooltip window that informs about the supported CAN FD clock frequency was added to the Target Hardware dialog box
  • Activation and unlocking of the CANopen firmware was added
  • Switching of the firmware operation mode was added
  • Statistic values Unique ID 0, 1, 2 and 3 were added
  • New possibility to set the Module ID to ANY
  • Some minor improvements

Bug fixes:

  • In the Symbols layout view, the tooltip window did not display the correct MSB and LSB values of the corresponding element
  • A entered Function parameter value was not applied if the mouse was used to select a different parameter value edit field
  • An active feedback output and the corresponding input inverter of a digital function block were not correctly restored when loading a configuration or when changing to another digital function
  • In the Connect dialog box and the Target Hardware dialog box the Preset and Bit Rate drop-down lists were not refreshed when the bit rates or presets definition was changed
  • If the selected hardware did support CAN FD, the Manage Bit Rates command always used the FD bit rates for default selection even if CAN FD was not selected
  • In the Target Hardware dialog box unsupported bit rate presets could be selected
  • Error Active/Passive CAN controller states were not displayed for connections using compatible CAN interfaces; instead, the old-style BUSHEAVY indicator was shown
  • Double-clicking on a variable in the Symbols layout could raise an Access Violation error
  • Loading of unsupported board types was not handled correctly
  • Corrected the display name of PCAN-MicroMod FD Analog 1
  • Removed some memory leaks
  • Some minor bug fixes

Changes:

  • 'Direction: Reverse' is set as default when the 'Export into Symbols file' dialog box is used the first time
  • Floating-point values can be specified for the frequency range of digital outputs instead of Integer values


Download

2019-08-27 - Version 1.0.0

  • First release