We use cookies on our website to provide you with the best possible service and to further improve our website. By clicking the "Accept All" button, you agree to the use of all cookies. You can limit the cookies used by clicking on "Accept selection". Further information and an option to revoke your selection can be found in our privacy policy.

Necessary:

These cookies are necessary for basic functionality. This allows you to register on our website and forum or order products with our online shop.

Statistics:

With these cookies, we collect anonymized usage data for our website. For example, we can see which content is interesting for our visitors and which resolutions are used. We use the information to optimize our website to provide you with the best possible user experience.

Necessary
Statistics

show more

PCAN-MiniDisplay - Firmware Version History

2020-04-30 - Version 1.4.2

Improvements:

  • Added support for digital output in scenes
  • New parameter "keep previous value" added for digital output in scenes


Download Package

2019-11-21 - Version 1.4.0

Improvement:

  • Trace Messages: If nothing is selected to be traced, a warning shows "No trace data selected."

Bug fixes:

  • Trace Messages: If nothing was selected to be traced, the help file was not displayed

2019-10-08 - Version 1.3.12

Improvements:

  • Instruments: Added the keyword "protect=1" for section [global]. A compressed instrument is encrypted and does not run on another device

Bug fixes:

  • Data records of error frames were sometimes incorrect and did no contain the correct bus number
  • Data records of error-frames did not have the correct DLC (set to 4)
  • In case of a Bus-Off during transmission of tx-lists in a scene the bus was not set back to Bus-On again

2019-10-01 - Version 1.3.11

Improvements:

  • Added the trace modes multi file and single session. This allows continuous logging onto the SD card

2019-09-02 - Version 1.3.10

Improvements:

  • Added differnt logger operation modes: single file, multi file linear, and multi file circular

2019-08-27 - Version 1.3.9

Bug fixes:

  • Timestamps are only 32 bit, in case the logger splits the data into several files it was not possible to create the correct timestamp per file
  • The header of each log file now contains a 64 bit timestamp. An update of the PEAK-Converter tool is required to make use of the 64 bit timestamps

2019-03-25 - Version 1.3.8 / 1.3.7

Improvements:

  • Enums are now supported in instruments
  • The format-strimg for labels can be omitted if only a simple number should be displayed (e,g, "%d", "%u", "%f" ). The format-string is automatically selected based on the datatype of the variable (unsigned, signed, float, string, enum)
  • The format-string can be used for more complex outputs, e.g. "%03d °C", "%5.2f mV" etc.
  • The plotter can scroll the x-axis. For this, define scroll_x=[0|1]

2019-01-07 - Version 1.3.6

Bug fixes:

  • In case of a multiplexed messages, the wrong variable was used as a multiplexer. Therefore the multiplexed variables were not updated correctly

2018-09-10 - Version 1.3.5

Improvements:

  • Instruments: No text output while a compressed instrument is loaded
  • Instruments: The display brightness can be adjusted via CAN. For this, define the variable "dev_brightness" with type unsigned and the value range is 0 to 100. If a scene makes use of this, brightness is set to minimum at startup of the scene
  • Instruments: The buzzer can be activated via CAN. For this, define the variable "dev_buzzer" with type unsigned. Value range is 0 (off) and 1-14 for different predefined sounds
  • Instruments: The keys enter, up, and down can be addressed via CAN. For this, define the variable "dev_keys" with type unsigned and the values 1=Enter, 2=KeyUp, and 3=KeyDown

2018-08-20 - Version 1.3.4

Bug fixes:

  • Correction in parsing of *.ins files
  • Scenes did not schow ° when using newer modules with TFT display

2018-06-21 - Version 1.3.3

Bug fixes:

  • Plotter could not display signed data correctly

2018-05-24 - Version 1.3.2

  • Bug fix: Tracer settings (type of trace) were not stored correctly, therfore automatic trace start after power-on did not capture the desired data.

2017-12-07 - Version 1.3.1

  • Added a new option to the device settings to swap the display orientation (0°/180°)
  • Added a new feature: Scenes can now transmit CAN frame sequences. For this there are 3 types of transmit lists: init list, cyclic list, and exit list

2017-07-28 - Version 1.2.3

  • The transparency parameter of instruments can now be set to 2 which enables a recalculation of overlapping transparent instruments

2017-06-17 - Version 1.2.1

  • Several changes in Device Settings due to the new hardware version and to increase the readability

Important note:

Older PCAN MiniDisplays without casing (IPEH-002262, before serial number 150) and casing (IPEH-002262-KSM01, before serial number 12215) must be updated to the firmware 1.1.7 before they can be updated to firmware 1.2.1 or higher.

2017-06-19 - Version 1.1.7

Improvements:

  • In addition to decimal, the parameter muxvalue of instruments can be defined in hexadecimal
  • Added a new tracer option to set a shutdown time (Tracer timeout) in case no error/data is received for this time
  • Added display dimming with timeout

Bug fixes:

  • Bitrate detection was not working correctly since version 1.1.3
  • The playing back traces with channel 2 was not working
  • Fixed reset of CAN channel 2

2016-11-04 - Version 1.1.5

Improvements:

  • Added logging and playback support
  • The log file size can be selected by user now
  • The information to be logged can be chosen by the user (error, data, or error and data)
  • New for instrument panels: Possibility to use multiplexed CAN signals
  • New for instrument panels: if a signal of a label has a timeout, a special timeout string can be displayed

2015-06-22 - Version 1.1.2

Improvements:

  • Added help files
  • When an instrument file is quit, the system returns to the Instrument Selection menu instead of the Main menu

Bug fixes:

  • Displaying Bitmaps did not work since version 1.1.0
  • The plotter draws one horizontal line out of its range

2015-05-28 - Version 1.1.0

Bug fixes:

  • Depending on the memory card type, access to the memory card might fail
  • The CAN filter could be set incorrectly after enter/exit the Device Settings menu
  • Shutdown did not always work

Firmware updates prior to product release ...