2020-03-13 - Version 1.15.1
- If a message gateway triggered a function block which contained a conditional statement, this condition was always true
- Improvement: A message gateway did trigger a function block only when mode was set to "message trigger". Now the trigger is also valid if the mode is set to "direct copy"
PEAK-Flash tool with embedded firmware file
2019-11-19 - Version 1.15.0
Bug fixes:
- Clear CF-card did not work correctly when is was done using a "default value" (at startup of the module) and the card was already full
2018-06-08 - Version 1.14.4
Improvements:
- Added "MaxSectorsToWrite" variable for CF trace
Bug fixes:
- The internal hashkey calculation from CAN ID lead to an index outside of the corresponding data array. This could cause problems with the memory or processor crashes
- Routing tables were not processed correctly
- Fixed CAN_SetTransceiverMode() for HS8_GE. Listen-only was not possible
2015-06-01 - Version 1.14
Changes:
- Number of transmit messages increased from 120 to 350
- Number of data objects increased from 257 to 1272
- Number of data objects that were saved to EEPROM was limited to 127
2015-03-31 - Version 1.13
New features:
- Multiplexer option for CAN variables added
- Scale/Offset calculation order can be swapped for transmit messages (make it compatible to PCAN-Explorer behavior)
2014-10-10 - Version 1.12
- Adjusted the Timing parameter for XMORE-CF-Cards
- Timeout of Selfhold signal freezed the Router Pro
- Fixed a problem with the Sleep-mode of the TH8056 transceiver (Single-wire)
- Concerning "Routing x to y, ex..." CAN-IDs are now limited to 2047. It was possible to enter higher values but this leads to a system freeze
- Trace Clear was deactivated completely
2013-04-03 - Version 1.9
Improved device resources:
- Receive messages quantity set from 50 to 120
- Transmit messages quantity set from 50 to 120
- Gateway messages quantity set from 50 to 120
- Defaults quantity set from 50 to 500
- Characteristic Curves quantity set from 10 to 20
- Enhanced error management concerning the CF card interaction
- Trace Clear is now inactive by default
- Logging Error Frames is now inactive by default
- Improved error management when the resources are exhausted
Please note: This version also includes the changes of revision 1.8.
2011-12-07 - Version 1.7
New configuration features:
- Logging of error frames is now switchable for each CAN channel
- Suppression of the configuration ID 7E7h is now switchable for each CAN channel
Bug Fix:
- Function block "hysteresis" now has a 5.th parameter "start mode"
Attention: Both features require an update of the PPCAN-Editor hardware profile. This profile is delivered with the PPCAN-Editor from version 2.0.4
2011-10-11 - Version 1.6
Improvements:
- Logging of CAN error frames. Attention: This feature requires a PEAK-Converter (PCAN-Trace Converter) from version 1.9.0
- Number of logging sessions is no longer limited to 16. Attention: This feature requires a PEAK-Converter (PCAN-Trace Converter) from version 1.9.0
Bug fix:
- Warning when exceeding hardware's resource limits. Attention: this feature requires a PPCAN-Editor 2 from version 2.0.3
2011-05-19 - Version 1.5
- Bug fix: Erroneous configuration may permanently block the device
- Added: "Route X to Y, all" can now be switched during runtime
- Changed device's resources:
- Characteristic Curves quantity set from 2 to 10
- Function Blocks quantity set from 50 to 120
2010-10-18 - Version 1.4
- Bug fix: Code incomplete for CAN channel 5 (CF card) (incl. extension of PEAK-Converter to 16 channels)
- Bug fix: Error when writing to EEPROM beyond 64 MB
- Changed device's resources:
- Receive messages quantity set from 35 to 50
- Transmit messages quantity set from 35 to 50
- Limits set from 10 to 5
- Strings set from 5 to 2
2010-04-20 - Version 1.2
- Various bug fixes
- First official release
2010-03-25 - Version 1.1
- Added new functions: real-time clock, beeper, and TJA1041 support