We use cookies on our website to provide you with the best possible service and to further improve our website. By clicking the "Accept All" button, you agree to the use of all cookies. You can limit the cookies used by clicking on "Accept selection". Further information and an option to revoke your selection can be found in our privacy policy.

Necessary:

These cookies are necessary for basic functionality. This allows you to register on our website and forum or order products with our online shop.

Statistics:

With these cookies, we collect anonymized usage data for our website. For example, we can see which content is interesting for our visitors and which resolutions are used. We use the information to optimize our website to provide you with the best possible user experience.

Necessary
Statistics

show more

2009-12-08 - PCAN-Explorer 5 - Version 5.0.4

Improvements:

  • Tracer: The Symbol column now also displays the name of an associated Multiplexer
  • Receive/Transmit window: Saving the message data is now possible in the Hex View via the context menu
  • Receive/Transmit window: Long Names of variables are now also shown in the Hint window when the mouse is positioned over a Variable in the Data column
  • Select Signals dialog box: Virtual signals are displayed in a separate category when the Category view is selected
  • J1939: Removed the restriction that Variables in large messages had to be byte-aligned when positioned beyond data byte 7

Bug fixes:

  • Several User Interface elements were not shown correctly if a larger text size (DPI) was selected in Windows
  • When trying to assign a keyboard shortcut to a command that did not have one initially, an Access Violation occurred
  • If the Transmit List contained one or more messages that were not assigned to any bus, executing one of the commands "Pause All" or "Resume All" produced an Access Violation
  • Object model: The TransmitMessages.Add method did not work
  • Output window: Selected text was not shown correctly on the "Macro" tab if a proportional font was used
  • When executing the "Reset Layout" command in the Options dialog box, a "Severe error" was reported if any documents were still open while resetting the layout
  • If the Signal display mode was set to "Long Name" in the Options dialog box, the Watch window didn’t show any text in the Name column if a Signal did not have a long name
  • Event handlers in VBS Macros did not work correctly
  • If a Floating window was closed and later opened again as an MDI child window, the MDI tab would appear but the window was outside the visible screen
  • If the main application window was maximized, activating and deactivating the Full Screen mode of a window restored the main window to its normal (not maximized) state
  • Some memory leaks were fixed
  • Transmitted RTR messages were not filtered correctly if a message filter contained a filter item of type "Adjust to Symbols"
  • Receive List: A comment, which was defined for a Variable, was not displayed as a hint if the mouse was positioned over a Variable in the data column

Changes, improvements, and bug fixes in the PCAN-Explorer Add-ins: 

  • Instruments Panel Add-in - Version 3.0.4.321 Details ...