Improvements:
- If a new J1939 transmit message is created and a symbol is selected from the list, the destination address used last is automatically selected.
- If a new project is created and closed without saving, the project's user interface layout no longer affects the default layout of PCAN-Explorer.
- Importing ASC files improved.
- Identical J1939 messages from different source addresses are now shown in different rows in the Receive list.
- Object model: The property Application.CurrentTime now always returns correct values, even if the current project does not contain any active connections.
- J1939 database updated to 2016-03.
- The J1939 database now includes SLOT values according to J1939-71 Appendix A. SPN and SLOT value assignments are used to show range names according to J1939-71 chapter 5.1.5.
- Some minor improvements and fixes.
Bug fixes:
- Access violations could occur when a J1939 project was loaded that contained fast cyclic transmit messages.
- If the Reset command was executed quickly several times in succession, the transmission of cyclic transmit messages was delayed more and more.
- If the default transmit list was cleared via the Clear All command and the project was then saved, all messages were available again after reloading the project.
- Scrolling the Macro Status window contents using the mouse wheel did not work properly with some mouse models.
- Raw variables decoded their data always beginning at data byte 0, ignoring their actual position in the message data.
- When a VBS macro accessed the property Tracer.Messages.Count, the application stopped responding.
- When a trace file was exported to a CSV file, no timestamps were written to the file if a differential timestamp format was selected.
- If a new pane was added to the Output Window via a VBS macro, an access violation occurred when the application was closed.
- When the transmit list contained simultaneous cyclic CAN and J1939 messages, the transmission time accuracy of the messages deteriorated.
- If the "Clear All" button in the Timeouts window was clicked while no project was open, an Access Violation occurred.
- The Watch window showed the physical unit behind a signal value even when an enum string was shown for the current signal value.
Changes, improvements, and bug fixes in the PCAN-Explorer Add-ins and PCAN-Symbol Editor:
Plotter Add-in - Version 2.4.1 Details ...
CANdb-Import Add-in - Version 3.0.14 Details ...
J1939 Add-in - Version 1.6.3 Details ...
PCAN-Symbol Editor - Version 3.2.1 Details ...