We use cookies on our website to provide you with the best possible service and to further improve our website. By clicking the "Accept All" button, you agree to the use of all cookies. You can limit the cookies used by clicking on "Accept selection". Further information and an option to revoke your selection can be found in our privacy policy.

Necessary:

These cookies are necessary for basic functionality. This allows you to register on our website and forum or order products with our online shop.

Statistics:

With these cookies, we collect anonymized usage data for our website. For example, we can see which content is interesting for our visitors and which resolutions are used. We use the information to optimize our website to provide you with the best possible user experience.

Necessary
Statistics

show more

PCAN-Repeater DR

CAN CC Repeater for Decoupling Bus Segments


All prices are plus the at present valid value added tax!

Stock information

  • IPEH-004038 - PCAN-Repeater DR - Out of stock! Expected to be available in approximately one week.

We gladly accept pre-orders (order.peak@hms-networks.com).

Description

The PCAN-Repeater DR establishes a galvanic isolation of up to 5 kV within a High-speed CAN bus. Both CAN ports are decoupled from each other and from the power supply. All message traffic including error frames is forwarded 1:1 between both ports. The PCAN-Repeater DR behaves passively and is transparent from the perspective of the CAN bus. LEDs display the current bus status.

The PCAN-Repeater DR finds application in the realization of long stub lines or the galvanic isolation of two CAN bus segments. With its DIN rail housing and extended temperature range support, it is suitable for use in an industrial environment. The PCAN-Repeater DR is designed for use in CAN CC buses, but can also be used in CAN FD buses with data bit rates up to 4 Mbit/s and nominal bit rates up to 1 Mbit/s.
 

Please note


Due to the CAN protocol, the maximum length of a CAN bus depends on the bit rate. Therefore, a bus cannot be extended with the PCAN-Repeater DR. The physical total length of the CAN bus is reduced with each built-in PCAN-Repeater DR according to its transit delay.

Technical Specifications

  • Two High-speed CAN ports (ISO 11898-2)
    • Compliant with CAN specifications 2.0A (11-bit ID) and 2.0B (29-bit ID)
    • Bit rates from 5 kbit/s up to 1 Mbit/s
    • Suitable for the use in CAN FD buses with data bit rates up to 4 Mbit/s and nominal bit rates up to 1 Mbit/s
    • NXP PCA82C251 CAN transceiver
  • Connections for CAN and power supply via 4-pin screw terminal block (Phoenix)
  • Galvanic isolation rated up to 5 kV according to IEC 60601-1, between both CAN ports and between CAN and power supply
  • Each CAN port can be selectively terminated
  • LEDs display CAN bus load and CAN errors (only for CAN 2.0 A/B)
  • Transit delay about 115 ns, which corresponds to a cable length of approximately 23 m
  • Voltage supply from 8 to 30 V
  • Plastic housing (width: 22.5 mm) for mounting on a DIN rail (DIN EN 60715 TH35)
  • Extended operating temperature range from -40 to +85 °C (-40 to +185 °F)

Scope of Supply

  • PCAN-Repeater DR in DIN rail plastic casing
  • 3 mating connectors for power supply and CAN connections (Phoenix Contact MSTB 2,5/4-ST BK - 1756298)
  • Manual in PDF format

Downloads

PCAN-Repeater DR manual

German English

More

Additional information

Accessories