We use cookies on our website to provide you with the best possible service and to further improve our website. By clicking the "Accept All" button, you agree to the use of all cookies. You can limit the cookies used by clicking on "Accept selection". Further information and an option to revoke your selection can be found in our privacy policy.

Necessary:

These cookies are necessary for basic functionality. This allows you to register on our website and forum or order products with our online shop.

Statistics:

With these cookies, we collect anonymized usage data for our website. For example, we can see which content is interesting for our visitors and which resolutions are used. We use the information to optimize our website to provide you with the best possible user experience.

Necessary
Statistics

show more

PCAN-Diag FD Editor Version History

2026-02-11 - Version 1.3.0

Improvements:

  • Added the ability to create and edit CAN transmit and sequence lists. With this improvement, PCAN-View is not needed anymore for the PCAN-Diag FD and was removed from the product download package.

Bug fixes:

  • A wrong DLC was used when converting transmit multiplexer symbols. Now the largest DLC is used.
  • CAN messages of transmit and sequence lists were not loaded correctly and could not be modified if the data length was 64
  • Minor text corrections and optimizations
  • The default bit rate lists have been updated
     

Please note: Downloadable only via the PCAN-Diag FD package. This software is not distributed individually.

Download

2022-10-05 - Version 1.2.0

Improvements:

  • Added the J1939 settings and management for custom PGs
  • Improved keyboard input to change dropdown properties directly with keyboard input
  • The start image 'intro_vert.bmp' is now also transferred if it is in the project directory

Bug fixes:

  • Once the Device Info window was displayed, the output for attaching or removing devices stopped working afterwards
  • The bit rates definition file 'bitrates.ini' next to the application was used and transferred even if a file existed in the project directory
  • The Output tabs had the wrong color
  • An incorrect help topic was opened for the Output window
  • The Output window had the input focus at startup
  • Under certain circumstances, selecting a tab via the context menu opened the wrong tab
  • The F1 key did not open a help topic for the Symbols tab if the Target Format drop-down list was active
  • Some text corrections in the XML files and the online help
     

2021-07-15 - Version 1.1.0

Improvements:

  • Supports new INI files with CAN bit rates that can optionally contain names for nominal data bit rates
  • Some values have been added and corrected in 'Settings' and 'Measurements'
  • The CAN bit rates have been adjusted
  • Enums with value ranges and user defined minimum and maximum values of Variables/Signals can now be used with Symbols files

Bug fixes:

  • When starting the software from the SD card of the PCAN-Diag FD, an error message 'Bitrates.ini not found' was displayed
  • When using Symbols files, default values of float and double Variables/Signals and signals with a length of more than 64 bits were not interpreted correctly
  • The CAN bit rate presets were not sorted correctly

Changes:

  • The user-specific combination of nominal and data bit rates has been removed from the user interface
     

2018-02-08 - Version 1.0.2

Improvements:

  • Predefined CAN bit rates were updated

Bug fixes:

  • CAN FD Symbols with a data length of more than 8 data bytes were not converted correctly
     

2017-11-24 - Version 1.0.1

Improvements:

  • Definition file was updated to match with PCAN-Diag FD firmware version 1.3.3
     

2017-06-12 - Version 1.0.0

  • First official release