Diese Website verwendet Cookies für Analysen, die Anmeldung im Online-Shop und im Forum sowie die Durchführung einer Bestellung. Durch die Nutzung dieser Website erklären Sie sich mit der Verwendung von Cookies einverstanden. Detaillierte Informationen über deren Einsatz finden Sie in unserer Datenschutzerklärung.

OK Datenschutz

Instruments Panel Add-in 6 Version History

2018-01-12 - Version 6.1.1 - Part of PCAN-Explorer 6.1.1

Bug fixes:

  • Copy/paste of a Button, LED, or Label whose caption was cleared recreated a new caption for the new control


2017-09-15 - Version 6.1.0 - Part of PCAN-Explorer 6.1.0

Improvements:

  • New "Enabled" property that controls the enabled state of controls


2017-06-09 - Version 6.0.12 - Part of PCAN-Explorer 6.0.12

Improvements:

  • New "Visible" property that controls the visiblity of controls in Run Mode

Bug fixes:

  • A repeating error message "Out of system resources" was displayed when either the height or the width of a control was reduced to 0
  • Assigning a signal to a selection of multiple controls with drag-and-drop failed, only the control under the mouse cursor got the signal
  • Object Model: After calling Scenes.Remove for the active scene, the Instruments Panel window was empty and no further operation was possible
  • Object Model: Calling Scenes.ClearAll triggered an Access Violation error
  • Object Model: Iterating through the Scene.Controls collection with for..each was not possible


2017-04-07 - Version 6.0.11- Part of PCAN-Explorer 6.0.11

Improvements:

  • New possibility to hide the Set button of a ValueEdit control
  • When the ValueEdit caption is cleared, the other ValueEdit parts are realigned to use the free space

Bug fixes:

  • There was no way to change the font of the ValueEdit caption
  • Changing the different ValueEdit fonts did not always have the expected effect
  • The Value property of a ValueEdit control was not shown in the Properties window


2017-01-16 - Version 6.0.10 - Part of PCAN-Explorer 6.0.10

Improvements:

  • Default On Value of Toggle Switch and Rocker Switch controls changed to 1
  • New possibility to set the Minimium and Maximum values of controls in the Properties window according to the value range of assigned signals


2016-11-04 - Version 6.0.7 - Part of PCAN-Explorer 6.0.7

Improvements:

  • The window content of a panel is updated immediately while scrolling with the scroll bar
  • The mouse wheel can be used to scroll a panel vertically

Bug fixes:

  • Changing the value of the Slider, Dial, or any other active control did not automatically transmit the updated signal value on the CAN bus if the signal was defined in a format version 6.0 symbols file
  • After opening an Instruments Panel file, the values in ValueEdit controls were displayed with highlighted text if the assigned signal used an Enum
  • The AnalogMeter 360 instrument was not updated when the value of the assigned signal changed
  • Some command states were not updated correctly and some keyboard shortcuts were missing in the context menus


2016-09-02 - Version 6.0.3 - Part of PCAN-Explorer 6.0.3

Bug fixes:

  • If the caption of a Trend control was customized, e.g. set as empty, the original caption was restored when some other controls were inserted into the panel with a copy-paste operation
  • Selecting a scene via the panel's context menu did not work
  • Sometimes cyclic transmit messages of active controls were not correctly started when the Run mode was enabled


2016-06-09 - Version 6.0.1 - Part of PCAN-Explorer 6.0.1

  • New instruments like an analog 360° gauge and a shape element for displaying squares, rectangles, circles, and ellipses
  • First Release