Diese Website verwendet Cookies für Analysen, die Anmeldung im Online-Shop und im Forum sowie die Durchführung einer Bestellung. Durch die Nutzung dieser Website erklären Sie sich mit der Verwendung von Cookies einverstanden. Detaillierte Informationen über deren Einsatz finden Sie in unserer Datenschutzerklärung.

OK Datenschutz

PCAN-MiniDisplay - Version History

2018-05-24 - Version 1.3.2

  • Bug fix: Tracer settings (type of trace) were not stored correctly, therfore automatic trace start after power-on did not capture the desired data.


2017-12-07 - Version 1.3.1

  • Added a new option to the device settings to swap the display orientation (0°/180°)
  • Added a new feature: Scenes can now transmit CAN frame sequences. For this there are 3 types of transmit lists: init list, cyclic list, and exit list


2017-07-28 - Version 1.2.3

  • The transparency parameter of instruments can now be set to 2 which enables a recalculation of overlapping transparent instruments


2017-06-17 - Version 1.2.1

Important note:

Older PCAN MiniDisplays without casing (IPEH-002262, before serial number 150) and casing (IPEH-002262-KSM01, before serial number 12215) must be updated to the firmware 1.1.7 before they can be updated to firmware 1.2.1 or higher.

  • Several changes in Device Settings due to the new hardware version and to increase the readability


2017-06-19 - Version 1.1.7

Improvements:

  • In addition to decimal, the parameter muxvalue of instruments can be defined in hexadecimal
  • Added a new tracer option to set a shutdown time (Tracer timeout) in case no error/data is received for this time
  • Added display dimming with timeout

Bug fixes:

  • Bitrate detection was not working correctly since version 1.1.3
  • The playing back traces with channel 2 was not working
  • Fixed reset of CAN channel 2


2016-11-04 - Version 1.1.5

Improvements:

  • Added logging and playback support
  • The log file size can be selected by user now
  • The information to be logged can be chosen by the user (error, data, or error and data)
  • New for instrument panels: Possibility to use multiplexed CAN signals
  • New for instrument panels: if a signal of a label has a timeout, a special timeout string can be displayed


2015-06-22 - Version 1.1.2

Improvements:

  • Added help files
  • When an instrument file is quit, the system returns to the Instrument Selection menu instead of the Main menu

Bug fixes:

  • Displaying Bitmaps did not work since version 1.1.0
  • The plotter draws one horizontal line out of its range


2015-05-28 - Version 1.1.0

Bug fixes:

  • Depending on the memory card type, access to the memory card might fail
  • The CAN filter could be set incorrectly after enter/exit the Device Settings menu
  • Shutdown did not always work


Firmware updates prior to product release ...