Diese Website verwendet Cookies für Analysen, die Anmeldung im Online-Shop und im Forum sowie die Durchführung einer Bestellung. Durch die Nutzung dieser Website erklären Sie sich mit der Verwendung von Cookies einverstanden. Detaillierte Informationen über deren Einsatz finden Sie in unserer Datenschutzerklärung.

OK Datenschutz

PCAN-MicroMod FD - Firmware Version History

2020-08-02 - Version 1.9.10

Bug fixes:

  • Inversion of digital inputs did not work always correctly

2020-07-09 - Version 1.9.9

Bug fixes:

  • Motherboard Analog1: negative analog input values were incorrect in case a scale value not equal 1 was used

2020-06-05 - Version 1.9.8

  • In case the configuration of a DR module is invalid, but bit rate turn switches are valid, the CAN engine is initialized according to the switch position and the module runs in Standard (not CANopen) mode
  • The bit rate table for non-DR modules did contain a samplepoint of 87.5% for 500 kbit/s, CAN FD without BRSs. Corrected to a samplepoint of 80%

2020-05-12 - Version 1.9.7

Improvements:

  • Enhanced PEAK-Flash identification

Bug fixes:

  • PCAN-MicroMod FD Analog 1 modules with serial numbers from 00100 to 00143 might return incorrect Analog Input (16-bit) results in +/-20V measurement range (~2.5% too high)

2020-04-09 - Version 1.9.6

Improvements:

  • Added more configuration and board specific information when detecting the CPU module or the different motherboards with the configuration software
  • Added new module descriptions for PEAK-Flash

Changes:

  • SSP (secondary sample point) of data bit rates is set to 80% for bit rates >= 2.5 Mbit/s
  • If no valid configuration is loaded the module blinks red and green alternately
  • Frequency of digital outputs in PWM mode was changed from integer to float

Bug fixes:

  • Updated the bit rate table due to some bugs
  • PWM measurement of channel 1,3, and 5 was inactive

2020-02-14 - Version 1.9.5

  • Improvement: New scale calibration for +/-20V range of 16-bit analog inputs

2019-12-18 - Version 1.9.2

  • Bug fix: Reading module information did not initialize transfer counter correctly

Version 1.9

  • Bug fix for digital inputs: Option to invert the signal was missing in the configuration

Version 1.8

  • I2C-EEPROM was removed. Binary configuration is now stored in QSPI flash

2019-08-28 - Version 1.6

  • First official release